ebook img

AOP Series D Trunnion Mounted Ball Valves PDF

21 Pages·2010·0.48 MB·English
by  
Save to my drive
Quick download
Download
Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.

Preview AOP Series D Trunnion Mounted Ball Valves

INSTALLATION, OPERATION AND MAINTENANCE MANUAL AOP SERIES D TRUNNION BALL VALVE, 2”FP – 6”RP CONTENTS 1. Parts list……………………... 2 2. Description……..…………… 10 3. Safety information’s…….……… 10 4. Installation and storing… 10 5. Operation …….……… 12 6. Maintenance…………………. 12 7. D valve Reconditioning……… 14 7.1 D valve disassembly………. 14 7.2.a. Lever valve assembly …… 16 7.2.b. Gear valve assembly …… 19 8. Troubleshooting.......................... 21 IOM-BLV-D-006 PAGE 1 of 21 REV.01 Figure 1 – D Series-Standard Seat (class 150-900) – BARE STEM (see parts list below) IOM-BLV-D-006 PAGE 2 of 21 REV.01 Parts list – D Series Standard Seat 150-900 class– BARE STEM (reference Figure 1): Item Qty Description 1 1 BODY 2 1 ADAPTER- CLOSURE 3 1 BALL 4 1 STEM 5 1 LOWER TRUNNION 6 2 SEAT SUBASSEMBLY (SEAT RING + SEAT INSERT) 7 1 BONNET (GLAND PLATE) 8 1 ADAPTER PLATE- GEAR 9 * ADAPTER STUDS 10 * ADAPTER NUTS 11 * CAP SCREW SOCKET HEAD- BONNET 12 * CAP SCREW SOCKET HEAD- LOWER TRUNNION 13 * CAP SCREW SOCKET HEAD- ADAPTER PLATE 14 1 O-RING, ADAPTER 15 1 O-RING, STEM 16 2 O-RING – SEAT MAIN SEAL 17 1 O-RING, BONNET 18 1 O-RING, LOWER TRUNNION 19 1 BACK-UP RING, BONNET (NOT SHOWN- 900/1500 CLASS ONLY) 20 1 BACK-UP RING, STEM (NOT SHOWN- 900/1500 CLASS ONLY) 21 1 BACK-UP RING, TRUNNION (NOT SHOWN- 900/1500 CLASS ONLY) 22 1 BACK-UP RING, ADAPTER (NOT SHOWN- 900/1500 CLASS ONLY) 23 1 FIRE SAFE SEAL, TRUNNION 24 1 FIRE SAFE SEAL, ADAPTER 25 1 FIRE SAFE SEAL, BONNET 26 1 FIRE SAFE SEAL, STEM 27 1 GLAND BUSHING 28 1 BEARING RADIAL – DU - STEM 29 1 BEARING RADIAL – DU - TRUNNION 30 1 BEARING THRUST – DU - STEM 31 2 SPRINGS- SEAT 32 2 DRIVE PINS - STEM 33 34 2 TORQUE PIN 35 1 STEM KEY 36 1 FITTING- STEM 37 1 VENT/ DRAIN FITTING 38 1 BODY GREASE INJECTION FITTING * QUANTITIES DEPENDING ON SIZE AND CLASS IOM-BLV-D-006 PAGE 3 of 21 REV.01 Figure 2 – D Series-Standard Seat (class 150-900) – LEVER OPERATED (see parts list below) IOM-BLV-D-006 PAGE 4 of 21 REV.01 Parts list – D Series Standard Seat 150-900 class– LEVER OPERATED (reference Figure 2): Item Qty Description 1 1 BODY 2 1 ADAPTER- CLOSURE 3 1 BALL 4 1 STEM 5 1 LOWER TRUNNION 6 2 SEAT SUBASSEMBLY (SEAT RING + SEAT INSERT) 7 1 BONNET (GLAND PLATE) 8 1 LOCKING BEARING HOUSING FOR 2FP UP 4RP VALVES —OR ADAPTER PLATE- GEAR FOR 4FP AND 6RP VALVES 9 * ADAPTER STUDS 10 * ADAPTER NUTS 11 * CAP SCREW SOCKET HEAD- BONNET 12 * CAP SCREW SOCKET HEAD- LOWER TRUNNION 13 * CAP SCREW SOCKET HEAD- BEARING HOUSING OR ADAPTER PLATE (SEE ITEM 8) 14 1 O-RING, ADAPTER 15 1 O-RING, STEM 16 2 O-RING – SEAT MAIN SEAL 17 1 O-RING, BONNET 18 1 O-RING, LOWER TRUNNION 19 1 BACK-UP RING, BONNET (NOT SHOWN- 900/1500 CLASS ONLY) 20 1 BACK-UP RING, STEM (NOT SHOWN- 900/1500 CLASS ONLY) 21 1 BACK-UP RING, TRUNNION (NOT SHOWN- 900/1500 CLASS ONLY) 22 1 BACK-UP RING, ADAPTER (NOT SHOWN- 900/1500 CLASS ONLY) 23 1 FIRE SAFE SEAL, TRUNNION 24 1 FIRE SAFE SEAL, ADAPTER 25 1 FIRE SAFE SEAL, BONNET 26 1 FIRE SAFE SEAL, STEM 27 1 GLAND BUSHING 28 1 BEARING RADIAL – DU - STEM 29 1 BEARING RADIAL – DU - TRUNNION 30 1 BEARING THRUST – DU - STEM 31 2 SPRINGS- SEAT 32 2 DRIVE PINS - STEM 33 1 STOP PLATE 34 2 TORQUE PIN 35 36 1 FITTING- STEM 37 1 VENT/ DRAIN FITTING 38 1 BODY GREASE INJECTION FITTING 39 1 SNAP RING 40 1 STOP PLATE CAP SCREW- ONLY ON 4FP AND 6RP VALVE 41 1 LEVER SUBASSEMBLY- NOT SHOWN * QUANTITIES DEPENDING ON SIZE AND CLASS IOM-BLV-D-006 PAGE 5 of 21 REV.01 Figure 3:D Series Bare Stem Valve – Lubricated Seat - 1500 Class IOM-BLV-D-006 PAGE 6 of 21 REV.01 Parts list: D Series Lubricated Seat 1500 class– BARE STEM (reference Figure 3): Item Qty Description 1 1 BODY 2 1 ADAPTER- CLOSURE 3 1 BALL 4 1 STEM 5 1 TRUNNION 6 2 SEAT SUBASSEMBLY (SEAT RING + SEAT INSERT) 7 1 BONNET (GLAND PLATE) 8 1 TRUNNION COVER 9 1 GEAR PLATE 10 * ADAPTER STUDS 11 * ADAPTER NUTS 12 * CAP SCREW SOCKET HEAD- BONNET 13 * CAP SCREW SOCKET HEAD- TRUNNION COVER 14 * CAP SCREW SOCKET HEAD- ADAPTER PLATE 15 1 O-RING, ADAPTER 16 1 O-RING, STEM 17 2 O-RING – SEAT MAIN SEAL 18 2 O-RING – SEAT SECONDARY SEAL 19 1 O-RING, BONNET 20 1 O-RING, TRUNNION 21 1 BACK-UP RING, BONNET 22 2 BACK-UP RING, SEAT MAIN SEAL 23 1 BACK-UP RING, STEM 24 1 BACK-UP RING, TRUNNION 25 1 BACK-UP RING, ADAPTER 26 1 FIRE SAFE SEAL, TRUNNION COVER 27 1 FIRE SAFE SEAL, ADAPTER 28 1 FIRE SAFE SEAL, BONNET 29 1 FIRE SAFE SEAL, STEM 30 1 GLAND BUSHING 31 1 BEARING RADIAL – DU - STEM 32 1 BEARING RADIAL – DU - TRUNNION 33 1 BEARING THRUST – DU - STEM 34 2 SPRINGS WAVE - SEAT 35 2 DRIVE PINS - STEM 36 37 2 TORQUE PIN 38 1 STEM KEY 39 1 FITTING- STEM 40 1 BODY VENT/ DRAIN FITTING 41 2 SEAT GREASE INJECTION FITTING 42 2 INTERNAL CHECK VALVE (BELOW GREASE FITTING) 43 1 BODY VENT PLUG * QUANTITIES DEPENDING ON SIZE AND CLASS IOM-BLV-D-006 PAGE 7 of 21 REV.01 Figure 4 – D Series Lever Operated Valve – Lubricated Seats – 1500 Class IOM-BLV-D-006 PAGE 8 of 21 REV.01 Parts list – D Series Lubricated Seat 1500 class– LEVER OPERATED (reference Figure 4): Item Qty Description 1 1 BODY 2 1 ADAPTER- CLOSURE 3 1 BALL 4 1 STEM 5 1 TRUNNION 6 2 SEAT SUBASSEMBLY (SEAT RING + SEAT INSERT) 7 1 BONNET (GLAND PLATE) 8 1 TRUNNION COVER 9 1 LOCKING BEARING HOUSING FOR 2FP UP 4RP VALVES —OR ADAPTER PLATE- GEAR FOR 4FP AND 6RP VALVES 10 * ADAPTER STUDS 11 * ADAPTER NUTS 12 * CAP SCREW SOCKET HEAD- BONNET 13 * CAP SCREW SOCKET HEAD- TRUNNION COVER 14 * CAP SCREW SOCKET HEAD- ADAPTER PLATE 15 1 O-RING, ADAPTER 16 1 O-RING, STEM 17 2 O-RING – SEAT MAIN SEAL 18 2 O-RING – SEAT SECONDARY SEAL 19 1 O-RING, BONNET 20 1 O-RING, TRUNNION 21 1 BACK-UP RING, BONNET 22 2 BACK-UP RING, SEAT MAIN SEAL 23 1 BACK-UP RING, STEM 24 1 BACK-UP RING, TRUNNION 25 1 BACK-UP RING, ADAPTER 26 1 FIRE SAFE SEAL, TRUNNION COVER 27 1 FIRE SAFE SEAL, ADAPTER 28 1 FIRE SAFE SEAL, BONNET 29 1 FIRE SAFE SEAL, STEM 30 1 GLAND BUSHING 31 1 BEARING RADIAL – DU - STEM 32 1 BEARING RADIAL – DU - TRUNNION 33 1 BEARING THRUST – DU - STEM 34 2 SPRINGS WAVE - SEAT 35 2 DRIVE PINS - STEM 36 1 LOCKING STOP PLATE 37 2 TORQUE PIN 38 39 1 FITTING- STEM 40 1 BODY VENT/ DRAIN FITTING 41 2 SEAT GREASE INJECTION FITTING 42 2 INTERNAL CHECK VALVE (BELOW GREASE FITTING) 43 1 BODY VENT PLUG 44 1 SNAP RING 45 1 STOP PLATE CAP SCREW- ONLY ON 4FP AND 6RP VALVE 46 1 LEVER SUBASSEMBLY- NOT SHOWN * QUANTITIES DEPENDING ON SIZE AND CLASS IOM-BLV-D-006 PAGE 9 of 21 REV.01 2. Description D series ball valves 2” FP to 6” RP are full bore, through conduit, bi-directional, anti-blowout stem, double block and bleed with trunnion mounted ball for easy operation. These valves are equipped with seats with plastic insert; self relieve type seats to eliminate cavity pressure lock. The trunnion ball valve uses metal- backed self lubricating PTFE sleeve bearings and thrust washers to reduce torque. The stem and lower trunnion is separated from the ball to eliminate side loads. The lever and wrench head can be easily removed/ reassembled by means of set screws. The handwheel can be removed from the gear shaft by taking out the split pin. 3. Safety Information’s Valves shall be operated and maintained strictly in accordance with these procedures. Operation or maintenance outside of these procedures constitutes abuse of the product and voids all warranty and claims. When special operation is required, a formal written request to the company must be made for approval to operate in this manner if warranty and product liability is to be maintained. Before any work is performed on a valve, personnel working on the valve must obtain the proper work permits required by his employer. Personnel shall always use safety precautions set forth by the law and regulations required by his employer. Personnel shall also be aware that any venting or draining of fluids from the valve shall be done in accordance with safety and environmental procedures in force at the particular location. The maintenance personnel doing the repairs should be well trained, and familiar with all of the information contained in this manual. The valves shall be appropriately used for the intended purpose. Any safety or protection devices on the valve shall not be permanently removed or altered unless written approval is received from AOP representative. Transport, unpacking, lifting, connections to the different types of systems (electric, pneumatic, hydraulic systems, etc.) shall be made by expert and qualified personnel Should any difficulties or abnormalities arise which cannot be solved by the technician, contact AOP representative. Any servicing not covered by these instructions must be made by an authorized service center, after preliminary approval has been given by AOP representative. 4. Installation and storing Valves delivered by AOP After the valves have been assembled and tested, the valves are drained and painted. Sealing surfaces of connection flanges are greased and covered by protectors. All valves are delivered in fully open position, unless is actuated with a normal close position actuator. If the valve is lever operated, the lever may be separately packaged for easier handling and transportation. If the valve has a gear operator, the gear is installed on the valve and factory adjusted for open and closed position. The gear handwheel may be separately packaged for easier handling and transportation. IOM-BLV-D-006 PAGE 10 of 21 REV.01

See more

The list of books you might like

Most books are stored in the elastic cloud where traffic is expensive. For this reason, we have a limit on daily download.